DXD-330A 3HP Single Speed - LX Alternative
Direct Replacement
LX LP300 3HP 1 Speed is a great alternative to DXD-330A
High Performance and Large Flow
The LX LP series hot tub pumps are one of the most common single speed pumps used on Chinese manufactured hot tubs and swim spas as well as many other newer hot tub and swim spa brands appearing on the European market.
The LP series of pumps will serve as a booster pump to deliver a high volume of water through hot tub jets.
If you require a 2 speed pump from LX, please see our LX WP Series.
The LP Series is also ideal for use with
- Cycling water for fish ponds, including those that require salt water or actual seawater.
- Weak corrosive liquids such as weak acids (without solid granules)
- For circulating fluids for use in workshops for cooling.
This is a direct replacement for a LX LP300 Single Speed Spa Pump with 2" connections manufactured AFTER / POST 2008 (See IMPORTANT NOTE below)
The LP series is also the pump of choice for both Jacuzzi and Sundance spas, replacing the discontinued Theramax pumps and can also be used to replace similar higher priced pumps from other manufactures at a more economical price.
IMPORTANT NOTE: Older (Pre 2008) LP & WP pumps and wet ends are manufactured with a shorter section (approx. 15mm) and discharge port (approx. 30mm). You may find on some hot tubs with very rigid plumbing that the newer versions will not line up with the pipework. The wet end faceplate moulding is different and they are also "open" on the rear of the wet end casing as opposed to the pre 08 wet ends which are encased. SEE IMAGES FOR REFERENCE
If you are replacing a pre '08 version (the wet end is labelled B351-03) we find that the Waterway Executive equivalent tends to have a better fit.
Also a great alternative to the RWA 3HP Single Speed
Dimensions L x W x H | 400x200x220mm |
HEAD - H max | 17m |
FLOW - Q max | 635lpm |
Type / Speed | 1 Speed |
Model | LP300 |
Horsepower | 3.0 Hp |
MPN | LP300 |
Voltage / Frequency | 220-240V / 50Hz |
Amp Draw | 13 A |
Power - P1 | 2.20 kW |
RPM | 2900 |
Capacitor Size(s) | 50 µF |
Union Connection Ref | 2.0 " (Inch) |
Impeller Part No. | B351-04 |
Impeller Diameter | 116mm |
Impeller Vane Gap | 12.5mm |
Shaft Seal Type | Type A |
Spare Parts Available | Yes - See Spare Parts List |
Hi, I'm needing to replace our pump on our balboa hot tub. I it's a dxd-330 AS 220-240v. Could you recommend the correct pump I will require? Many Thanks
Hello, I belive our SKU PMP-5762 would be the correct replacement. LX wP300